<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-05 18-51-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 70 dBuV Classic
Pilot RDS Phase Difference
7.1 kHz 3.5 kHz 78 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 19007 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,2 dBr 1,70 dBr 2,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Kyrie Eleison (Trad) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2025/01/05 18.50.25 Total samples: 19007 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 2,8 dBr MIN: 0,2 dBr AVE: 1,70 dBr % above 12,2 dBr: 0,0 Last value: 2,7 dBr (2025/01/05 18.50.24) 18.36 18.38 18.40 18.42 18.44 18.46 18.48 18.50 -1 0 1 2 3 Pm [dBr]